🚩Conveyor Troubleshooting
If conveyor doesn’t run
Pulse Switch Failure
Look at tunnel watch screen for error
Reach out to maintenance to enable simulated pulse
Low Hydraulic Oil
Check for a leak
Refill it
Debris stuck in chain
Like empty bottles, straps, ropes, etc
Move at all grates and clear the debris
E-Stop buttons
Pull out all E-Stops in Tunnel, electrical panel, Buff N Dry, Petit, etc)
Tripped breaker
Force back on and let maintenance know
If conveyor shoots out a bunch rollers
This usually means the tunnel is expecting to receive a car but there's no car
Cover the entry eyes with your hand to run a ghost car
Roller up solenoid could be stuck in the up position
Tell maintenance
If conveyor doesn’t shoot up rollers
Roller up solenoid could be stuck in the down position
Use the manual lever until maintenance can replace it
Check air pressure gauge for roller up solenoid
Let maintenance know
If pit overflows
Throw a sump pump in the pit until maintenance gets there
Unclog drain / call maintenance
Pressing send on the loader screen and no roller comes up
Check the entry arch pucks to see if they are illuminated. This would mean the tunnel is ready to receive the vehicle. This might mean the roller up solenoid is bad.
If the entry arch pucks are not illuminated, there could be a communication error between the loader screen and the controller.